PV Grid-tied Residential Inverter and Integrated AC/DC Disconnect
Installation and Operation Manual
49
GFI Negative Jumper
Figure B-5 GFI Negative Jumper in J10 Port
6. Locate the pre-installed negative GFI jumper into port J10. Remove
the negative jumper and replace with a positive ground jumper.
Negative GFI Positive GFI
Figure B-6 Negative and Positive GFI Jumpers
!
WARNING
Do not connect or disconnect the GFI jumper shown in
Figure C-1 while the inverter is supplied with DC or AC
power.
!
AVERTISSEMENT
Ne pas connecter ou déconnecter la bretelle du différentiel
présenté à la Figure C-1 lorsque l’onduleur est alimenté en
CC ou CA.
Resume the installation procedures.