PV Powered PVP4800 Información técnica Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
PV Grid-tied Residential Inverter and Integrated AC/DC Disconnect
Installation and Operation Manual
9
Inside Screw
Figure 3-3 Inverter’s Inside Screw Below the Power Board
Securing the Integrated AC/DC Disconnect
When the inverters screws are completely installed, the Integrated AC/DC
Disconnect also needs to be secured to the wall.
1. Make sure the AC/DC ON/OFF switch is in the OFF position.
2. Remove the screws around the edge of the disconnect’s front cover and
remove the lid.
3. Secure the disconnect to the wall at the two internal locations using
a rubber washer with a #13 zinc or stainless steel screw. The rubber
washer seals the hole. The screws must secure to a single stud for
rigidity. Refer to the wall mount template for specic locations.
If at any time the inverter is removed for service, the Integrated AC/DC
Disconnect remains in place.
Inverter
Mounting Bracket
GFI fuse external
access port
Integrated AC/DC
Disconnect
Figure 3-4 Inverter and Integrated AC/DC
Disconnect with Mounting Bracket
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 83 84

Comentarios a estos manuales