PV Grid-tied Residential Inverter and Integrated AC/DC Disconnect
Installation and Operation Manual
31
Red LED is illuminated when:
The PV array voltage is not within required operating limits, such as:
At sunset, when the inverter turns off for the night.
When clouds reduce the amount of available sunlight or when por-
tions of the PV array are covered with debris.
Any time the DC output from the PV array drops below the in-
verters minimum DC operating voltage, the inverter turns off.
The DC polarity input has reversed conductors. No message is dis-
played in this situation.
When the array is once again exposed to enough sunlight, the green LED
illuminates, the inverters auto-start feature begins, and after ve minutes
the inverter begins to export power.
If the red LED continues to illuminate when there is sufcient sunlight
for operation, verify that no wiring connections are loose. If the wiring
is secure, see Chapter 6,
Troubleshooting
on page 33 for additional
information.
The vacuum uorescent display (VFD) indicates the inverters status
and real-time power output into the AC grid. This display provides the
following information:
Inverter model type.
AC power produced in real time (watts).
Lifetime energy produced (kWh).
AC voltage in real time (VAC).
PV voltage input in real time (VDC).
During start-up, a count-down timer.
Fault code message if a fault exists or recently occurred.
Normal Display Cycle
The display changes every two seconds to show a different set of
information as shown in Figure 5-1 and Figure 5-2.
Screen 1 Screen 2 Screen 3
Figure 5-1 Normal Startup Screens