PV Powered 3000 Manual de instalación Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
Electrical Connection SMA Solar Technology AG
34 SB25_30-IA-IEN115050 Installation Manual
5. Check the strings for ground faults as described in Section 9.3.1 "Checking the PV Array for
Earth Faults" (page57).
6. Check the DC connectors for correct polarity and connect them.
To unlock the DC connectors, see Section 7.2 "Opening the Inverter" (page45).
NOTICE!
Exceeding the maximum input voltage can destroy the inverter.
If the voltage of the PV modules exceeds the maximum input voltage of the inverter, it can
be destroyed by the overvoltage.
This will void all warranty claims.
Do not connect strings with an open-circuit voltage greater than the maximum input
voltage of the inverter.
Check the plant design.
DANGER!
Risk of lethal electric shock.
Do not connect strings with ground faults.
•First, rectify the earth fault in the respective string.
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 75 76

Comentarios a estos manuales

Sin comentarios