SMA Solar Technology AG Electrical Connection
Installation Guide SB25_30-IEN092520 21
12. Screw the threaded sleeve onto the socket element.
13. Screw the pressure screw tightly onto the threaded sleeve.
AC connection socket has been screwed together.
14. Close the socket element with the provided protective cap, if it is not immediately connected to
the Sunny Boy.
15. Insert the AC connection socket into the AC socket on the Sunny Boy. If necessary, remove the
protective cap beforehand.
16. Screw the AC connection socket's threaded ring
tightly onto the AC socket on the Sunny Boy. The
threaded ring serves to seal and relieve strain on
the AC connection socket.
The AC cable is connected to the Sunny Boy.
Size used
PG13.5
The fastening case along with the sealing ring is pressed into the
threaded sleeve and can no longer be seen.
PG16
DANGER!
Danger to life due to high voltages in the Sunny Boy!
Do not switch on the line circuit breaker until the Sunny Boy is securely closed and
the PV generator has been connected.