7.Troubleshooting
When an unpredictable error occurs, MEAN WELL advises the user to check the error
code and notify the local system installation vendors to repair the inverter.
Error Code
01
02
03
05
06
07
08
11
12
14
15
09
Error Cause Error Cause Suggested Solution
Grid Voltage
Abnormal
1. Grid voltage too high or
too low
2. Grid connection contact
resistance too high
3. Grid disconnected
4.AC cable damaged
1. Grid voltage too high
2.Grid connection contact
resistance too high
contact is outside range
2. Check if circuit breaker has
been triggered
3.Increase wire diameter to
reduce resistance
1. Measure whether connection
between grid voltage and GSI
Grid Voltage High
for past 10 minutes
Measure whether connection
between grid voltage and GSI
contact is too high
Grid Frequency
Abnormal
Grid frequency outside
acceptable range
Measure whether grid
frequency is outside range
PV End Voltage
High
DC voltage too high
1.Disconnect the GSI from
the PV module immediately
to protect the GSI
2. Check PV module voltage;
wait for a suitable input
condition to reconnect the
GSI
*The GSI may already be
damaged
PV End Voltage Low DC voltage too low Wait for greater sunshine!
Leakage Current
Abnormal
Insulation Abnormal
Relay Connection
Abnormal
Fan Lock
PWM Abnormal
DC Bus Voltage High
Over Temperature
Protection
Excessive leakage current
may be due to ground fault
Installation error or
foreign object entered
Internal fault
1. Foreign object stuck
2.Fan fault
Internal Fault
Internal Fault
1. Operation temperature
too high
2.Fan lock
Check for a ground fault
Check whether equipment
is installed correctly or if a
foreign object has entered
Reset and check again. If
fault is frequent, please notify
MEAN WELL
Reset and check again. If
fault is frequent, please notify
MEAN WELL
Reset and check again. If
fault is frequent, please notify
MEAN WELL
1. Clean fan
2.Change fan
1. Check if ventilation
passage is clear or if ambient
temperature is too high
2.Clean or change fan
Table 7-1