DC input: Uses 2 sets of MC4 connectors.
AC output: Uses Wieland Flange connector.
5.4 Electrical Connections
5.4.1 Connection Requirements
Before wiring, fix the inverter, and check the distribution panel to see if the
circuit break is in its OFF state, to ensure the safety of the electrical technician.
Please choose wire diameter according to our advised values (5.4.2), and
conform to local electrical code wiring standards to guarantee the quality
of the wiring.
Caution :
Grounding screw must be screwed on.
Grounding screw
Warning!
Warning!
◎Electrical connection should only be made after making sure the
◎Before connecting the PV module, please make sure the GSI-3000,
4600 is disconnected from the utility grid.
◎One circuit breaker should only be connected to one inverter, please
exposed to sunlight to prevent electrical shock.
◎When installing the PV module, please make sure it is not directly
◎Connection of the GSI-3000,4600 to the utility grid must be operated
◎Mixing of DC inputs in forbidden.
by qualified personnel, and must be licensed by the local authorities.
GSI-3000,4600 is thoroughly installed.
do not connect multiple inverters with one circuit breaker.
(DC : 25A/600V ; AC : 30A/250V)
Example: GSI-4600 has two sets of DC input channels: A and B. When
a PV module is connected to the positive terminal of A(B)
and negative terminal of B(A), it is called a mixed connection.
12
Grounding Position
8.Use the grounding screw to connect the grounding wire to the GSI.