9. SPECIFICATIONS
modEll PRotEct PV 4600
dc inPut
Nominal DC voltage 600 VDC
Max. PV open voltage 750 VDC
MPPT range 125–700 VDC
Working Range 100–750 VDC
Number of MPP Tracker 3
Max. Input current 8.5 ADC per Tracker
ac outPut
Output power 4600 W
Max. power 5000 W
Operational Voltage 184–264.5 VAC
Operational Frequency 50 Hz
Current distortion < 3%
Power Factor (cos ϕ) ~ 1
systEm
Display
LCD Display
2 line, 16 Char.
Max. efficiency > 96%
Euro efficiency > 94%
Protection degree IP 65
Operation temp. -20 °C – 55 °C
Humidity
0–95%
non-condensing
Standby power ~ 8 W
Acoustic noise level < 35 dBA
Comm. Interface
Standard RS232
Optional RS485
and others
mEchanical
W x D x H (mm) 430 x 530 x 134
Weight (kg) 27