6. OPERATION OF THE PROTECT PV 4600
6.1 auto-PowER
The PV-Inverter starts up automatically once DC-power from the PV-
Panel is sufficient. There are 3 modes of operation.
6.2 oPERating modEs
1. Normal
In this mode, the PV-Inverter automatically detects the system status
and selects the best mode of operation.
If the power from the PV-Panel is higher than 150VDC, the supply is
converted to AC and fed in to the grid. If the power is less than 100
VDC, the PV-Inverter displays “Waiting”. During the wait state, the
device uses minimal power from the PV-Panel to monitor the system
status. During normal mode, the green LED is on.