Installation
6.5 Connections of the PV power system
Step3: Use the bracket to install the inverter onto the narrow vertical panel (or wall). Ensure the upper corner
of inverter is attached onto the bracket.
Step4: Make sure the bracket and the inverter’s right side screw hole are in line and matching well, fix the screw
into the hole and screw into the inverter tightly.
Step5: If necessary lock the inverter and the bracket with padlock (not included) for safety.
● PV String
SolarRiver inverters 3300TL, 4400TL and 5200TL have facility to connect two strings of PV moduleswhile
the other models can only take one module string. Use only PV modules with excellent performance and
reliable quality. Open-circuit voltage of modules connected in series should be <Max. DC input voltage of
the inverters (Ref Table 3) and the operating voltage at all times should be within the MPPT voltage range.
Only use good quality PV cables to connect modules to inverter. Normally the voltage drop between modules
and inverter could be about 1-2%. Hence inverter should be installed as close to the PV module as possible
to reduce cable losses.
Table 3 Max. DC Voltage of inverters
Model
Max. DC voltage
SolarRiver
1100TL
SolarRiver
1600TL
SolarRiver
2300TL
SolarRiver
3000TL
SolarRiver
3300TL
SolarRiver
3680TL
SolarRiver
4400TL
SolarRiver
5200TL
500V 550V
15
Note!
Please don’t connect the PV panel positive or negative to ground.
Figure 11 Use of Multimeter to measure module array voltage
Warning!
PV modules carry high DC voltage which is dangerous, please comply with all
electrical safety rules and regulations when working.
Warning!
In case of any faults with module arrays, do not connect the inverter to the
arrays.